{"id":741,"date":"2022-03-06T20:22:49","date_gmt":"2022-03-06T20:22:49","guid":{"rendered":"https:\/\/capeelectric.in\/blog\/?p=741"},"modified":"2024-04-23T07:44:46","modified_gmt":"2024-04-23T07:44:46","slug":"neutral-and-body-earthing-of-transformer-and-dg-part-1","status":"publish","type":"post","link":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/","title":{"rendered":"Neutral and body earthing of Transformer and DG Part -1"},"content":{"rendered":"\r\n<div class=\"OFA52E\">\r\n<div class=\"cD_92h UitnHM\" tabindex=\"-1\" data-hook=\"post-title\">\r\n<div class=\"OFA52E\">\r\n<div class=\"cD_92h UitnHM\" tabindex=\"-1\" data-hook=\"post-title\">\r\n<div class=\"OFA52E\">\r\n<div class=\"cD_92h UitnHM\" tabindex=\"-1\" data-hook=\"post-title\">\r\n<div class=\"OFA52E\">\r\n<div class=\"cD_92h UitnHM\" tabindex=\"-1\" data-hook=\"post-title\">\r\n<div class=\"OFA52E\">\r\n<div class=\"cD_92h UitnHM\" tabindex=\"-1\" data-hook=\"post-title\">\r\n<div class=\"OFA52E\">\r\n<div class=\"cD_92h UitnHM\" tabindex=\"-1\" data-hook=\"post-title\">\r\n<div class=\"OFA52E\">\r\n<div class=\"cD_92h UitnHM\" tabindex=\"-1\" data-hook=\"post-title\">\r\n<div class=\"OFA52E\">\r\n<div class=\"cD_92h UitnHM\" tabindex=\"-1\" data-hook=\"post-title\">\r\n<h1 class=\"UbhFJ7 nkqC0Q blog-post-title-font blog-post-title-color blog-text-color post-title blog-hover-container-element-color FG3qXk blog-post-page-title-font\" data-hook=\"post-title\"><span class=\"post-title__text blog-post-title-font blog-post-title-color\"><span class=\"blog-post-title-font blog-post-title-color\">Neutral and body earthing of Transformer and DG Part -1<\/span><\/span><\/h1>\r\n<\/div>\r\n<\/div>\r\n<div class=\"nLG8d5\" data-hook=\"post-description\">\r\n<article class=\"blog-post-page-font\">\r\n<div class=\"post-content__body\">\r\n<div class=\"moHCnT\">\r\n<div class=\"moHCnT\">\r\n<div class=\"fTEXDR A2sIZ4 QEEfz0\" data-rce-version=\"9.14.8\">\r\n<div class=\"itVXy dojW8l s6hjqn _8a1b4\" dir=\"ltr\" data-id=\"rich-content-viewer\">\r\n<div class=\"mhGZq BAGeNT\">\r\n<h4 id=\"viewer-foo\" class=\"_2k8TI Y9Dpf OZy-3 cDpYU ok2w4y bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>Earthing at Industrial and Commercial Premises<\/strong><\/span><\/h4>\r\n<h4 id=\"viewer-eik1e\" class=\"_2k8TI Y9Dpf OZy-3 cDpYU ok2w4y bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><em><strong>(Two for neutral, Two for body)<\/strong><\/em><\/span><\/h4>\r\n<p id=\"viewer-873kj\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">Industrial and commercial premises the electrical inspectors after conducting inspection used to make the following comment (or comments with similar meaning) with a reference to regulation 41 of <a class=\"TWoY9 itht3\" href=\"https:\/\/cea.nic.in\/regulations-category\/measures-relating-to-safety-and-electric-supply\/?lang=en\" target=\"_blank\" rel=\"noopener noreferrer\" data-hook=\"linkViewer\"><u class=\"D-jZk\">CEA regulation &#8220;<strong>Measures relating to safety and electric supply 2010<\/strong><\/u><\/a>&#8220;. <\/span><\/p>\r\n<ol class=\"public-DraftStyleDefault-ol\">\r\n<li id=\"viewer-bc1kp\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size public-DraftStyleDefault-reset OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Transformer bodies shall be double earthed with <u class=\"D-jZk\">(SIZE)<\/u> GI flats and they shall be connected to two separate and independent earth electrodes.<\/p>\r\n<\/li>\r\n<li class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size public-DraftStyleDefault-reset OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Transformer Neutrals shall be double earthed with <u class=\"D-jZk\">(SIZE)<\/u> copper flats and they shall be connected to two separate and independent earth electrodes.<\/p>\r\n<\/li>\r\n<li>The lightning arrester shall be independently earthed with <u class=\"D-jZk\">(SIZE, copper \/ GI)<\/u> flats and they shall be brought down by insulators.<\/li>\r\n<\/ol>\r\n<p id=\"viewer-ee7jg\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><em>Note: The electrical inspectors rarely refer the above claims with regulation 48 (Connection with earth for apparatus exceeding 650V).<\/em><\/span><\/p>\r\n<p id=\"viewer-63m9v\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">Users are compelled to do as per these comments (by the inspector).<\/span><\/p>\r\n<p id=\"viewer-2oai6\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>The first part of this blog is to find out the basics of the recommendation by electrical inspector w.r.t regulations and code of practices. This regulation is one of the most mis interpreted regulation and is one of the reasons for electrical accidents in the country.<\/strong><\/span><\/p>\r\n<div data-hook=\"rcv-block14\">\u00a0<\/div>\r\n<div id=\"viewer-ceqj0\" class=\"QHjDE rzoRKE\">\r\n<div class=\"gO6aa y8JqQg y8JqQg flaqF\">\r\n<div class=\"Q6a5A\" data-hook=\"imageViewer\">\r\n<div id=\"new-image4835\" class=\"vBPBf L9OMM\"><img decoding=\"async\" src=\"https:\/\/static.wixstatic.com\/media\/f51a2a_358e95cab4254ef48a4ea54773ab96ca~mv2.png\/v1\/fill\/w_925,h_418,al_c,q_90,usm_0.66_1.00_0.01,enc_auto\/f51a2a_358e95cab4254ef48a4ea54773ab96ca~mv2.png\" alt=\"\" data-pin-url=\"https:\/\/capedigital.wixsite.com\/demo\/post\/two-independent-earth-electrode\" data-pin-media=\"https:\/\/static.wixstatic.com\/media\/f51a2a_358e95cab4254ef48a4ea54773ab96ca~mv2.png\/v1\/fill\/w_1127,h_509,al_c,q_90\/f51a2a_358e95cab4254ef48a4ea54773ab96ca~mv2.png\" data-load-done=\"\" \/><\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div data-hook=\"rcv-block16\">\u00a0<\/div>\r\n<p id=\"viewer-5lmjr\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>Analysis of the regulation Part 1<\/strong><\/span><\/p>\r\n<p id=\"viewer-egqq\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">sub regulation 1, 12 and 13 are referred in this part<\/span><\/p>\r\n<p id=\"viewer-tjp0g8fyx\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>From the 2010 regulation<\/strong><\/span><\/p>\r\n<div id=\"viewer-5h5rr\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\">The following conditions shall apply to the connection with earth of systems at voltage normally exceeding 125 V but not exceeding 650 V, namely: &#8211;<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><\/div>\r\n<p id=\"viewer-8oan6\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">i. neutral conductor of a 3-phase, 4-wire system and the middle conductor of a 2-phase, 3-wire system shall be earthed by not less than two separate and distinct connections with a minimum of two different earth electrodes or such large number as may be necessary to bring the earth resistance to a satisfactory value both at the generating station and at the sub-station.<\/span><\/p>\r\n<div id=\"viewer-aa4lp\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\">xii. the frame of every generator, stationary motor, portable motor, and the metallic parts, not intended as conductors, of all transformers and any other apparatus used for regulating or controlling electricity, and all electricity consuming apparatus, of voltage exceeding 250 V but not exceeding 650 V shall be earthed by the owner by two separate and distinct connections with earth.<\/span><\/div>\r\n<div id=\"viewer-9523r\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\">xiii. neutral point of every generator and transformer shall be earthed by connecting it to the earthing system by not less than two separate and distinct connections.<\/span><\/div>\r\n<div id=\"viewer-d4aqi\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><\/div>\r\n<p id=\"viewer-1pdhb\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><strong><span class=\"B2EFF public-DraftStyleDefault-ltr\">Definitions <\/span><\/strong><\/p>\r\n<div id=\"viewer-5h08q\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u201cearthed&#8221; or &#8220;connected with earth&#8221; means connected with the general mass of earth in such manner as to ensure at all times an immediate discharge of electricity without danger;<\/span><\/div>\r\n<div id=\"viewer-7ouqv\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\">&#8220;earthing system&#8221; means an electrical system in which all the conductors and appliances are earthed;<\/span><\/div>\r\n<div id=\"viewer-25du6\" class=\"QHjDE rzoRKE\">\r\n<div class=\"VcB4o\">\u00a0<\/div>\r\n<\/div>\r\n<p id=\"viewer-ed1fv\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">Sub regulation 1 is applicable to the neutral conductor, 12 about frame of DG and transformer and 13 about neutral of a transformer.<\/span><\/p>\r\n<ol class=\"public-DraftStyleDefault-ol\">\r\n<li id=\"viewer-8doka\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size public-DraftStyleDefault-reset OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Neutral conductor shall be connected to two separate earth electrodes (in soil).<\/p>\r\n<\/li>\r\n<li id=\"viewer-fhm2j\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Frame of DG and TR shall be earthed by two separate and distinct connections with earth.<\/p>\r\n<\/li>\r\n<li id=\"viewer-91ven\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Neutral of DG and TR shall be earthed by connecting to earthing system (2 connections).<\/p>\r\n<\/li>\r\n<\/ol>\r\n<p id=\"viewer-5fumq\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">From the regulation and the definitions it is clear that body require two connections with earth and not to earth electrode and Neutral require connection with earthing system and not to earth electrode.<\/span><\/p>\r\n<p id=\"viewer-245fc\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><em>(Note: earthed, connected with earth and earthing system doesn&#8217;t mean earth electrode in soil, but by some means to earth)<\/em><\/span><\/p>\r\n<div data-hook=\"rcv-block26\">\r\n<p id=\"viewer-qgoej1hak\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>Background of the regulation (41 \u2013 1, 12 &amp; 13):<\/strong> These regulations are continuation from IE rule 1956 and E rule 1937.<\/span><\/p>\r\n<div id=\"viewer-2n6gv\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><\/div>\r\n<p id=\"viewer-fo6t9\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>From 61 (a) of IE rule 1956 (neutral conductor)<\/strong>: (a) Neutral conductor of a 3 phase, 4 wire system and the middle conductor of a 2 phase, 3-wire system shall be earthed by not less than two separate and distinct connections with a minimum of two different earth electrodes or such large number as may be necessary to bring the earth resistance to a satisfactory value both at the generating station and at the sub-station. The earth electrodes so provided, may be inter-connected to reduce earth resistance. It may also be earthed at one or more points along the distribution system or service line in addition to any connection with earth which may be at the consumer\u2019 s premises.<\/span><\/p>\r\n<div id=\"viewer-4vch1\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>From 61 (2) of IE rule 1956 (DG\/TR body<\/strong>): The frame of every generator, stationary motor, portable motor, and the metallic parts (not intended as conductors) of all transformers and any other apparatus used for regulating or controlling energy and all medium voltage energy consuming apparatus shall be earthed by<\/span><\/div>\r\n<p id=\"viewer-4v4lc\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">the owner by two separate and distinct connections with earth.<\/span><\/p>\r\n<div id=\"viewer-c5esv\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>From 67 (1A,(a) of IE rule 1956 (neutral point)<\/strong>: (a) The neutral point of every generator and transformer shall be earthed by connecting it to the earthing system as defined in Rule 61(4) and hereinabove by not less than two separate and distinct connections:<\/span><\/div>\r\n<div id=\"viewer-blvqk\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><\/div>\r\n<p id=\"viewer-f1h1u\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>From of 61 (4) IE rule 1956<\/strong>: All earthing system shall &#8211; (a) consist of equipotential bonding conductors capable of carrying the prospective earth fault current and a group of pipe\/rod\/plate electrodes for dissipating the current to the general mass of earth without exceeding the allowable temperature limits as per relevant Indian Standards in order to maintain all non-current carrying metal works reasonably at earth potential and to avoid dangerous contact potentials being developed on such metal works;<\/span><\/p>\r\n<div id=\"viewer-1k9k4\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\">(b) Limit earth resistance sufficiently low to permit adequate fault current for the operation of protective devices in time and to reduce neutral shifting;<\/span><\/div>\r\n<div id=\"viewer-f48po\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\">(c) be mechanically strong, withstand corrosion and retain electrical continuity during the life of the installation. All earthing systems shall be tested to ensure efficient earthing, before the electric supply lines or apparatus are energised.<\/span><\/div>\r\n<div>\u00a0<\/div>\r\n<div>\r\n<p id=\"viewer-j4sf95woy\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>From 1937 electricity rule (rule 58): <\/strong><\/span><\/p>\r\n<p id=\"viewer-99jpr\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">58. Connection with earth of a multi-wire system. In every distributing system in which there is a neutral conductor, where the pressure between the neutral conductor and an outer or phase conductor exceeds 125 volts, the neutral conductor shall be connected with earth by two separate and distinct connections from the neutral bus-bar and in accordance with the following provisions, namely:<\/span><\/p>\r\n<div id=\"viewer-caoun\" class=\"xVISr Y9Dpf OZy-3 _40ACk public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">\u00a0<\/span><span class=\"B2EFF public-DraftStyleDefault-ltr\">(a) the connection shall be made at one point only on each distinct system, namely, at the generating station or sub-station, or both, as the case may be, and the insulation of the system shall be maintained at all other parts;<\/span><\/div>\r\n<div>\u00a0<\/div>\r\n<\/div>\r\n<\/div>\r\n<p id=\"viewer-6jqmm\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">From the IE rule 1956, it is evident that the <strong>neutral conductor<\/strong> is connected to earth electrode, body to be &#8220;earthed&#8221; by two connections and neutral to be earthed to equipotential bonding conductor with two connections. The E. rule (1937) recommend connecting the neutral conductor at one point only in the bus bar.<\/span><\/p>\r\n<p id=\"viewer-v39b\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><a class=\"TWoY9 itht3\" href=\"https:\/\/www.solvelv.com\/_files\/ugd\/f51a2a_980d823c14d64fa99c0e547c583b3449.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" data-hook=\"linkViewer\"><u class=\"D-jZk\">Safety regulation (2010) 14, 15 and 16, (1956 IE rule 31, 32 &amp; 33) (E. rule 1937 40 &amp; 51) the recommended either TN-S &amp; TN-C-S system by the energy supplier.<\/u><\/a> How ever the wording used still follow the systems in 1937, as a result the definitions of some nomenclatures used in 2010 regulations do not exist and not practiced in the modern world. <\/span><\/p>\r\n<p id=\"viewer-147b2\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">In a TN-C-S system the PEN conductor must be earthed to earth electrode at distribution, as an open circuit PEN can induce full phase voltage on exposed metallic parts connected to the system downstream of the place of open circuit in PEN. In order to avoid such shock from the full phase voltage, the IS3043 clause 4 recommend using PME system at distribution. <em>(<\/em><a class=\"TWoY9 itht3\" href=\"https:\/\/www.ukpowernetworks.co.uk\/electricity\/earthing\" target=\"_blank\" rel=\"noopener noreferrer\" data-hook=\"linkViewer\"><em><u class=\"D-jZk\">Similar to PME system used in UK<\/u><\/em><\/a><em>, <\/em><a class=\"TWoY9 itht3\" href=\"https:\/\/electricians-success-academy.com\/learn\/what-is-men-system\" target=\"_blank\" rel=\"noopener noreferrer\" data-hook=\"linkViewer\"><em><u class=\"D-jZk\">multiple earthed neutral (MEN) in Australia<\/u><\/em><\/a><em> and New Zealand and, <\/em><a class=\"TWoY9 itht3\" href=\"https:\/\/ieeexplore.ieee.org\/document\/5380207\" target=\"_blank\" rel=\"noopener noreferrer\" data-hook=\"linkViewer\"><em><u class=\"D-jZk\">multi-grounded neutral (MGN) in North America<\/u><\/em><\/a><em>,) <\/em><\/span><\/p>\r\n<p id=\"viewer-aev8k\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><em>Note: the energy supply companies violate regulations 14 to 16 in India and provide a system earthing of TT, with earthed neutral at distribution which is a nonstandard system earthing. <\/em><\/span><\/p>\r\n<p id=\"viewer-9r3os\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">Coming back to the comments of electrical inspectors asking for each body and neutral of a source (such as DG\/TR) to \u201ctwo separate connections to earth electrode\u201d some time to \u201ccopper strip and copper plate for neutral\u201d or to \u201cGI strip and GI pipes for body\u201d does seems to be from the regulation or the IS code of practices.<\/span><\/p>\r\n<p id=\"viewer-chbks\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">Following the recommendation of the electrical inspector (two connection to earth electrode) have the following disadvantages.<\/span><\/p>\r\n<ol class=\"public-DraftStyleDefault-ol\">\r\n<li id=\"viewer-3v9el\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size public-DraftStyleDefault-reset OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Use of nonstandard system earthing by the industrial and commercial consumer.<\/p>\r\n<\/li>\r\n<li id=\"viewer-90pgg\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Nonoperation of protective device during fault which may lead to accidents such as electrocution and fire (fire due to short circuit).<\/p>\r\n<\/li>\r\n<li id=\"viewer-5fbd9\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Exceeds the power frequency with stand voltages of 3 kV (<a class=\"TWoY9 itht3\" href=\"https:\/\/cea.nic.in\/wp-content\/uploads\/regulations_cpt\/2020\/08\/reg_elec_plants_lines.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" data-hook=\"linkViewer\"><u class=\"D-jZk\">as stipulated in regulation 91 of Technical Standards for Construction of Electrical Plants and Electric Lines 2010<\/u><\/a>).<\/p>\r\n<\/li>\r\n<li id=\"viewer-3gesn\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Unreliable and non standard practices are followed for the electronic system affecting the reliability of electronics.<\/p>\r\n<\/li>\r\n<\/ol>\r\n<p id=\"viewer-3sfo5\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">Investigations in electricity related accidents shows that the recommendations by the electrical inspector (two separate connections to earth electrodes) are carried out in majority of the installations and is the reason for non-operation of protective device during earth fault, resulting in the accident..<\/span><\/p>\r\n<p id=\"viewer-8u7dd\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><em>(note: Some engineers claim the recommendation of inspector as TT, which is untrue as most industries interconnect these earth electrodes under the soil (similar to an inefficient TN-S system). <\/em><a class=\"TWoY9 itht3\" href=\"https:\/\/www.solvelv.com\/_files\/ugd\/f51a2a_88b7edd7c3814a08b4bbc26b23fbe2a3.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" data-hook=\"linkViewer\"><em><u class=\"D-jZk\">Protective equipotential bonding is not common in India, <\/u><\/em><\/a><em>and the power frequency stress voltages are not considered)<\/em><\/span><\/p>\r\n<h5 id=\"viewer-bgi4c\" class=\"iwbhW Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\"><strong>This recommendation by the electrical inspector is not only violation of the safety regulation, the code of practices and standards, but are the reason for electrical accidents such as electrocution and fire due to short circuit.<\/strong><\/span><\/h5>\r\n<h3 id=\"viewer-7am5\" class=\"iwbhW Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">Solution<\/span><\/h3>\r\n<p id=\"viewer-4qc7v\" class=\"xVISr Y9Dpf bCMSCT OZy-3 _40ACk Ecq9kg bCMSCT public-DraftStyleDefault-block-depth0 fixed-tab-size public-DraftStyleDefault-text-ltr\"><span class=\"B2EFF public-DraftStyleDefault-ltr\">IS3043: Code of practice of earthing fig 38 to 41 explains the correct method of earthing in Low Voltage DG. The below figure is 38 from IS3043, shows earthing of body and neural in a TN-C-S system with DG and manual change over. This is the correct method to be followed.<\/span><\/p>\r\n<div data-hook=\"rcv-block52\">\u00a0<\/div>\r\n<ol class=\"public-DraftStyleDefault-ol\">\r\n<li id=\"viewer-43oeo\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size public-DraftStyleDefault-reset OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">TN-S or TN-C-S to be adopted in an industrial or commercial premise with own transformer and DG<\/p>\r\n<\/li>\r\n<li id=\"viewer-4logf\" class=\"bCMSCT vBYpX _40ACk public-DraftStyleDefault-orderedListItem public-DraftStyleDefault-depth0 public-DraftStyleDefault-list-ltr fixed-tab-size OZy-3 _40ACk Ecq9kg bCMSCT\">\r\n<p class=\"Y9Dpf OZy-3 _40ACk Ecq9kg bCMSCT undefined\">Body and Neutral to be connected to MET (or equipotential bonding conductor).<\/p>\r\n<\/li>\r\n<\/ol>\r\n<div id=\"viewer-95pg1\" class=\"QHjDE rzoRKE\">\r\n<div class=\"Q6a5A\" tabindex=\"0\" role=\"button\" data-hook=\"imageViewer\">\r\n<div id=\"new-image4836\" class=\"vBPBf L9OMM\"><img decoding=\"async\" src=\"https:\/\/static.wixstatic.com\/media\/f51a2a_76feb31c519c4c5d9535ae143139056d~mv2.png\/v1\/fill\/w_925,h_401,al_c,q_90,usm_0.66_1.00_0.01,enc_auto\/f51a2a_76feb31c519c4c5d9535ae143139056d~mv2.png\" alt=\"\" data-pin-url=\"https:\/\/capedigital.wixsite.com\/demo\/post\/two-independent-earth-electrode\" data-pin-media=\"https:\/\/static.wixstatic.com\/media\/f51a2a_76feb31c519c4c5d9535ae143139056d~mv2.png\/v1\/fill\/w_3757,h_1629,al_c,q_95\/f51a2a_76feb31c519c4c5d9535ae143139056d~mv2.png\" data-load-done=\"\" \/><\/div>\r\n<div class=\"\">\u00a0<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/article>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n","protected":false},"excerpt":{"rendered":"<p>Neutral and body earthing of Transformer and DG Part -1 Earthing at Industrial and Commercial Premises (Two for neutral, Two for body) Industrial and commercial premises the electrical inspectors after conducting inspection used to make the following comment (or comments with similar meaning) with a reference to regulation 41 of CEA regulation &#8220;Measures relating to safety and electric supply 2010&#8220;. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":743,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"video","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-741","post","type-post","status-publish","format-video","has-post-thumbnail","hentry","category-uncategorized","post_format-post-format-video"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\r\n<title>Neutral and Body Earthing of Transformers and DGs: Part 1<\/title>\r\n<meta name=\"description\" content=\"Gain valuable insights into the critical aspects of neutral and body earthing for transformers and DGs in this informative Part 1 series\" \/>\r\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\r\n<link rel=\"canonical\" href=\"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/\" \/>\r\n<meta property=\"og:locale\" content=\"en_US\" \/>\r\n<meta property=\"og:type\" content=\"article\" \/>\r\n<meta property=\"og:title\" content=\"Neutral and Body Earthing of Transformers and DGs: Part 1\" \/>\r\n<meta property=\"og:description\" content=\"Gain valuable insights into the critical aspects of neutral and body earthing for transformers and DGs in this informative Part 1 series\" \/>\r\n<meta property=\"og:url\" content=\"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/\" \/>\r\n<meta property=\"og:site_name\" content=\"Cape Electric\" \/>\r\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/capeelectric\" \/>\r\n<meta property=\"article:published_time\" content=\"2022-03-06T20:22:49+00:00\" \/>\r\n<meta property=\"article:modified_time\" content=\"2024-04-23T07:44:46+00:00\" \/>\r\n<meta property=\"og:image\" content=\"https:\/\/www.capeelectric.in\/blog\/wp-content\/uploads\/2022\/03\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp\" \/>\r\n\t<meta property=\"og:image:width\" content=\"399\" \/>\r\n\t<meta property=\"og:image:height\" content=\"300\" \/>\r\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\r\n<meta name=\"author\" content=\"admin\" \/>\r\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\r\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\r\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/#\\\/schema\\\/person\\\/38a5e49baa70640241a895595d0e9479\"},\"headline\":\"Neutral and body earthing of Transformer and DG Part -1\",\"datePublished\":\"2022-03-06T20:22:49+00:00\",\"dateModified\":\"2024-04-23T07:44:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/\"},\"wordCount\":1592,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/\",\"url\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/\",\"name\":\"Neutral and Body Earthing of Transformers and DGs: Part 1\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp\",\"datePublished\":\"2022-03-06T20:22:49+00:00\",\"dateModified\":\"2024-04-23T07:44:46+00:00\",\"description\":\"Gain valuable insights into the critical aspects of neutral and body earthing for transformers and DGs in this informative Part 1 series\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp\",\"contentUrl\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp\",\"width\":399,\"height\":300,\"caption\":\"Body Earthing\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/neutral-and-body-earthing-of-transformer-and-dg-part-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Neutral and body earthing of Transformer and DG Part -1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/\",\"name\":\"Cape Electric\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/#organization\",\"name\":\"Cape Electric\",\"url\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/capeelectric.in\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/capeelectric.in\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/logo.png\",\"width\":250,\"height\":108,\"caption\":\"Cape Electric\"},\"image\":{\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/capeelectric\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/#\\\/schema\\\/person\\\/38a5e49baa70640241a895595d0e9479\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4a3112c8a592b10b8112a3e5f0bd042bdbb35c585d88e9d3e60c607346cc2acf?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4a3112c8a592b10b8112a3e5f0bd042bdbb35c585d88e9d3e60c607346cc2acf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4a3112c8a592b10b8112a3e5f0bd042bdbb35c585d88e9d3e60c607346cc2acf?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/capeelectric.in\\\/blog\"],\"url\":\"https:\\\/\\\/www.capeelectric.in\\\/blog\\\/author\\\/mwscape_5d5stdx9\\\/\"}]}<\/script>\r\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Neutral and Body Earthing of Transformers and DGs: Part 1","description":"Gain valuable insights into the critical aspects of neutral and body earthing for transformers and DGs in this informative Part 1 series","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/","og_locale":"en_US","og_type":"article","og_title":"Neutral and Body Earthing of Transformers and DGs: Part 1","og_description":"Gain valuable insights into the critical aspects of neutral and body earthing for transformers and DGs in this informative Part 1 series","og_url":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/","og_site_name":"Cape Electric","article_publisher":"https:\/\/www.facebook.com\/capeelectric","article_published_time":"2022-03-06T20:22:49+00:00","article_modified_time":"2024-04-23T07:44:46+00:00","og_image":[{"width":399,"height":300,"url":"https:\/\/www.capeelectric.in\/blog\/wp-content\/uploads\/2022\/03\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp","type":"image\/webp"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/#article","isPartOf":{"@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/"},"author":{"name":"admin","@id":"https:\/\/www.capeelectric.in\/blog\/#\/schema\/person\/38a5e49baa70640241a895595d0e9479"},"headline":"Neutral and body earthing of Transformer and DG Part -1","datePublished":"2022-03-06T20:22:49+00:00","dateModified":"2024-04-23T07:44:46+00:00","mainEntityOfPage":{"@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/"},"wordCount":1592,"commentCount":0,"publisher":{"@id":"https:\/\/www.capeelectric.in\/blog\/#organization"},"image":{"@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/#primaryimage"},"thumbnailUrl":"https:\/\/www.capeelectric.in\/blog\/wp-content\/uploads\/2022\/03\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp","inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/","url":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/","name":"Neutral and Body Earthing of Transformers and DGs: Part 1","isPartOf":{"@id":"https:\/\/www.capeelectric.in\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/#primaryimage"},"image":{"@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/#primaryimage"},"thumbnailUrl":"https:\/\/www.capeelectric.in\/blog\/wp-content\/uploads\/2022\/03\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp","datePublished":"2022-03-06T20:22:49+00:00","dateModified":"2024-04-23T07:44:46+00:00","description":"Gain valuable insights into the critical aspects of neutral and body earthing for transformers and DGs in this informative Part 1 series","breadcrumb":{"@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/#primaryimage","url":"https:\/\/www.capeelectric.in\/blog\/wp-content\/uploads\/2022\/03\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp","contentUrl":"https:\/\/www.capeelectric.in\/blog\/wp-content\/uploads\/2022\/03\/f51a2a_358e95cab4254ef48a4ea54773ab96camv2.webp","width":399,"height":300,"caption":"Body Earthing"},{"@type":"BreadcrumbList","@id":"https:\/\/www.capeelectric.in\/blog\/neutral-and-body-earthing-of-transformer-and-dg-part-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.capeelectric.in\/blog\/"},{"@type":"ListItem","position":2,"name":"Neutral and body earthing of Transformer and DG Part -1"}]},{"@type":"WebSite","@id":"https:\/\/www.capeelectric.in\/blog\/#website","url":"https:\/\/www.capeelectric.in\/blog\/","name":"Cape Electric","description":"","publisher":{"@id":"https:\/\/www.capeelectric.in\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.capeelectric.in\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.capeelectric.in\/blog\/#organization","name":"Cape Electric","url":"https:\/\/www.capeelectric.in\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.capeelectric.in\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/capeelectric.in\/blog\/wp-content\/uploads\/2023\/11\/logo.png","contentUrl":"https:\/\/capeelectric.in\/blog\/wp-content\/uploads\/2023\/11\/logo.png","width":250,"height":108,"caption":"Cape Electric"},"image":{"@id":"https:\/\/www.capeelectric.in\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/capeelectric"]},{"@type":"Person","@id":"https:\/\/www.capeelectric.in\/blog\/#\/schema\/person\/38a5e49baa70640241a895595d0e9479","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/4a3112c8a592b10b8112a3e5f0bd042bdbb35c585d88e9d3e60c607346cc2acf?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/4a3112c8a592b10b8112a3e5f0bd042bdbb35c585d88e9d3e60c607346cc2acf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/4a3112c8a592b10b8112a3e5f0bd042bdbb35c585d88e9d3e60c607346cc2acf?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/capeelectric.in\/blog"],"url":"https:\/\/www.capeelectric.in\/blog\/author\/mwscape_5d5stdx9\/"}]}},"_links":{"self":[{"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/posts\/741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/comments?post=741"}],"version-history":[{"count":5,"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/posts\/741\/revisions"}],"predecessor-version":[{"id":818,"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/posts\/741\/revisions\/818"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/media\/743"}],"wp:attachment":[{"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/media?parent=741"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/categories?post=741"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.capeelectric.in\/blog\/wp-json\/wp\/v2\/tags?post=741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}